the , . Then sometimes with no rhyme or reason the pump shuts down and will not come back on until after I turn off and on all breakers.
Weve not had this issue the past 2 years (we bought the house 2 years ago). Do you think the motor is fried as a result of no water running thru? My pump & filter are Haywards. Hi Rob, there could still have been some sand in the pipes yes, and thats probably the problem. Valves were replaced with pipe and silicone applied to gaskets and O-rings during install and again yesterday while I was checking this list. It seems the pump is more powerful than last year ? Step 3: When the instant salt level is stable (and the negative sign still present), cycle slide switch to 'Super Chlorinate' and back to 'Auto'. Please advise ). If pressure is lower than normal check for air leak on the suction side of the pump, or a clogged impeller, or low water level, stuck skimmer weir, or closed suction valves. Hi Patrick, so you have power from the breaker to the timer and to the switch. rialto grand polished porcelain tile 12x24, platypus gravityworks water filter system kit 2-liter, trinity basics ecostorage 5-tier nsf certified rack, Armstrong Human Resource Management 13th Edition Pdf, what is the newest lens for cataract surgery. Hi Frank, two possible reasons might be nighttime moisture (dew), or small insects, both contacting the circuit, on the timer or connected electrical outlet, and causing a brief short, which can trip the breaker. Put your foot on the motor and apply a little weight, to see if the noise stops. I could take a leap of faith by trying your suggestion of replacing the shaft seal first. Thanks for your insight. Filter runs fine at first, but then eventually loses its umph and then the return becomes minimal. Relays are usually small cubes, about 1 square, sometimes black, sometimes clear, mounted on a circuit board. Make sure that the drive is bonded with the bare copper wire and all four screws are secure on the drive. Hi Gail, overheating can be caused by the wrong wire size from breaker to motor, or loose wire connections, or over-voltage coming into motor, or lack of ventilation around the motor (mulch piled up, or big bushes close by, or placed in a box cover), but its can also be a fatal fault inside the motor. Hi Doug, could be a bad breaker, or bad wiring between the pump and breaker. I dont see any leaks n pressure seems little bit higher than normal. The most common cause for this is turning the valve with the pump on, or not pushing the valve handle down fully as the valve is re-positioned. If no power there, check the timer, if no power there, check the breaker, if no power there Is the main breaker in the house on? If the bolts do not tighten fully, it could be that the housing threaded receivers are loose and spinning as you try to tighten the bolts. 1.5 hayward pool pump motor clicks on and off rapidy. Hi Bryan, not normal but not uncommon. Alternatively, you can spin the shaft at the rear motor, with a 7/16 wrench inserted behind the stationary switch, on the slotted end of the motor shaft. Some pumps are a bit difficult to remove, even when you have removed the right bolts/clamp sometimes they need to be pried apart with a screwdriver, to separate the pump. Hi COnnie, great question! Connect the hose from the pump to PUMP, the wall return pipe to RETURN, and the backwash hose connects to the WASTE port, with the use of a hose adapter and clamp. The new pump runs great and only once every day or so do we notice that the pump is off and that the breaker is tripped. If any of these readings are outside limits, replace motor. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Exterior Wall Covering Materials, Hi Mark, there are salt and ozone resistant shaft seals that can be used, the salt could be the problem, or it could be caused by a water-hammer effect, where flowing water is shut-ff suddenly by a closed valve on the return side, or turning a filter valve while the pump is running. "@type": "ImageObject",
Products, Parts Remove and replace the two seal halves, in the same orientation as removed, spring half slides over impeller stem, donut half is pushed into seal plate. Do you have any suggestions? Seems impeller is not turning, does it turn both ways or one way? To remedy this, simply open up your pump, and clean out any rubbish. This usually means the motor needs to be replaced. Anything I can do on my own to fix this? 24V after the transformer is present. This is our second season for this pump. Have had it for 4-5 years and have had no issues. If a LED is ON, check to see if the flow switch was installed correctly. Perhaps you can replace it with a 20 amp breaker, of the same manufacturer, and youd be all set, or move some of the other devices to draw power from a different breaker. UNK the , . ), you have it primed full of water? If it does, check power inside of the back of the motor, with a test meter. Ive waited a few hours and tried again but no luck. I just want to clarify..we had a problem with the fuse box and its just been changed. Hi David, that would be my first guess, assuming that the power leads are tight, and connections or switches arent loose in the back. Hi Don, if you have four suction lines coming into the pump, that would be skimmer, skimmer, main drain and spa drain? it runs about 30 minutes and trips the breaker. Replace with identical MFD number, printed on capacitor. If you have other questions, you can email me Davy, at swimmers@intheswim.com. Even with the cells reverse polarity feature, the scale will still form on the plates. On a DE filter, water enters the tank through the bottom tank bulkhead, and is when the tank fills up, water is forced through the grids, and then up thru the manifold, and down the standpipe to the top exit bulkhead DE inside the grids, must have been missing an o-ring before, a push-pull valve plunger ring? Hi and thanks for all this knowledge! If youre reading this blog that means you need help troubleshooting your Hayward Aqua Rite salt system. It could also be the wiring from breaker to timer, or timer to pump, or just breaker to pump, if there is no timer or other switch (and if there is no other switch, the breaker is likely just worn out from overuse). The stationary switch copper tabs may be bent, or may have a wire crossing between them, have a loose screw or have some other issue that prevents it from opening, and releasing the capacitor. One thing I discovered is that if I place it in super chlorinate mode today, once the pool pump shuts down for the day, the next day when it turns back on, it will be back in regular chlorinate mode even if the switch is still in super chlorinate mode. The capacitor is like the battery in your car its needed to help get the pump up to speed (3200 RPMs) fast. Diffuser broke. have the pump motor rebuilt by replacing the bearings and shaft seal, or having an electric motor repair shop do it for you, or 2) replace the motor with an exact replacement motor + new shaft seal, or 3). Did I mention low water level, stuck skimmer weirs, or clogged skimmer baskets? . Please remove additional products. My client thinks the motor was 1hp, but he really not sure. I have a maxi-flo 2 and it just stopped working. Why is this happening? If so, the issue would reoccur again, after vacuuming usually. The electrician also installed w new capacitors on the pump and still same problem. Corrosion inside the plug or socket. I have a brand new Hayward super pump, replaced the one that just died. Took it to pool mart and they cleaned it out and said everything was fine inside it. If there is an external 2-speed timeclock, check the wiring, esp. Flip timeclock switch on, inspect time clock motor gears (Intermatic clocks) for good timer motor, and inspect wiring from timer to pump. Additional causes for low water flow in your pump are debris build-up or dirty equipment. The problem lies, where the power dies could be the breaker, time clock, outlet or at the terminal board. Hi Davy, Im trying to remove the impeller from a Hayward 1 HP superpump. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Hi, I have a filter timer and a cleaner timer that are side-by-side. Calling the pool builder for warranty info, too. When I installed the filter and pump the water in the filter came gushing out of the filter and the top mount was raised up even though the clamps were tightly screwed in place. It wont stop leaking. Work through the chart below if your heater displays the following error codes. Thanks in advance for any help you can provide, the pool should be done in the next few days and need to figure out this pump situation. Where can I get a new yellow wire to connect the motor to the switch and see if this solves my issue? Motor may still be good. how to watch past broadcasts on twitch. They can also fail if used on a salt pool (there are salt seals that can be used), or if the motor and shaft heats up to high temps. It looks like I need to change out the pump. Just replaced our pool pump, Hayward 1 hp self priming, super pump. If it is not, re-align your flow switch. The control panel says that theres a driver error. Hi Davy. Look closely at the centrifugal switch on the rear of the shaft, to be sure its tight and is not missing parts (like the springs), engage the switch by hand (power off), to be sure that the stationary switch (located at 6 oclock) is disengaging, or the two copper tabs separate. Now Im getting small air bubbles when the speed is on low. Also could be a loose stationary switch (motor rear, 6 oclock) or a loose centrifugal switch (motor rear, dead center). If from the center of the lid around the stem, you can replace the two small stem o-rings, but sometimes the stem is worn down and needs replacement. Hi Davy! I then plugged the pump into the outlet and it tripped again. How To Recalibrate The Average Salt Level. Your email address will not be published. Use a flashlight, and you should see gears moving thru the small view hole. That is the black cylinder in the rear of the motor, located at 9 oclock. If the switch does not close after the blower starts the control will go into lockout with the blower running. near the end of last season it started loosing its prime on and off. The second thing that can cause such a problem is if the pump is starved for water, cavitating, because it is too large (hp) for the piping system, or because incoming valves are closed, or pipes are plugged, or clogged. Replace with the exact same MFD number printed on the capacitor. Once it finishes calibrating, cycle the Main Switch from AUTO to SUPER CHLORINATE and back to AUTO. La mayora de las veces la vlvula de gas est cerrada, el tanque de propano est bajo, el encendedor est roto o el sensor de fuego no est colocado correctamente. After reinstalling, give it the full charge of DE powder, plus a little extra. The selector plug MUST be moved or the breaker will trip every time you try to start it up. It runs fine but no strong circulation. Lets see what we can do We have our pump timers to shut off at noonmany times, but all the time, they run past the specified shut off time. What should I do? The capacitor is the black cylinder on the left side, you can replace the capacitor at a low cost. If the set screws loosen, the impeller can slide forward and contact the pump housing, and grind both the bronze housing and bronze impeller down rapidly. Inspect the centrifugal switch on the end of the shaft and the stationary switch mounted at 6 oclock and contacting the central centrifugal switch make sure all are intact and tightly secured, and not bent, broken or affected by mud or insects. $8.99 $5.99 As low as $4.49 Dow Corning - Molykote 111 6 gram O-ring Silicone Lubricant and Sealant - Be sure to lube your O-rings to help prevent leaks. Hi, my above ground pool pump will run when not attached to the pool and there is no water in it, but when I get it hooked up to the pool and let the hoses and pump fill, it no longer turns on. The following steps will provide a guide on how to recalibrate a Hayward Aqua Rite. Another piece of information is that the board was replaced back around May of this year as well as the flow sensor. The cord does feel warm to the touch. No reset on the pump motor, but a little water on the wiring, and it will pop a GFI outlet. The centrifugal switch may be loose, or the stationary switch may be bent and not releasing. Any tips on getting the cover off to get to the capacitor (after removing the two screws)? Just opened my in ground pool went to turn the pump on and nothing. Motors have a thermal overload switch which will shut off the motor if it gets too hot to operate, and in such cases, it will turn itself back on again after it cools, usually in 15-20 mins. Could also be a vibration noise, or rocks/pebbles in the pump basket. What you have to do is drain the filter and remove all those tiny bolts, and pull out the entire nest assembly. A local motor shop could probably fix you up for $100, if you can remove the pump, and drive it to their shop. Hi Ernesto, hmmm, Im not quite sure, but sounds like it could be either low voltage, or a loose connection, or something mis-wired between the terminal board and the capacitor? While you have the nest assy out of the tank, after hosing it off, soak it in a DE filter cleaner, to remove any scale and oils. Just bought a new Hayward Perflex Series Extended Cycle Filtration Systems filter and cant get the motor to start. Bump shaft or diaphragm gasket? Not sure whats wrong. This is a salt pool not sure if that matters in the question. You could also use a Hayward 24 sand filter, item E3324. Write Review Hayward AquaTrol HP Main PCB | GLX-PCB-TROL-HP $375.97 Quantity $17.35 / Month * Platinum Preferred Manufacturer Proposition 65 Warning Display seems to be reading correctly and shows the cell is not generating. Put things back together and still have error. Is there something special I need to do when first installing the motor? power to my pool pump & timer quit working at the same time. Hi LInda, humming or buzzing, and not starting could be a few things first check that the shaft is spinning, either by spinning on the impeller end, or at the rear of the motor (power Off in both cases), to be sure the shaft is not bound up or seized. I just went out there to crank them up, after 10 minutes they shut off. Plate appeared to be good. You can remove the cartridge, reassemble the filter and run the system, just to verify that the cartridge is the problem. Hi Rob, I think its a one-year warranty? *If your water temperature reads 215 degrees F, the cell temperature sensor is shorted and your cell needs replacing. Try to spin the impeller with your fingers, or turn the motor shaft to check that it spins freely, or if not, put a wrench on the shaft and break the rust free. Conversely, and by the way, when pressure is much lower than normal, that indicates an obstruction before the filter, like clogged pump or skimmer baskets or an impeller clog. I would say you are likely needing a new motor, and pump. If not the skimmer being blocked, then its an air leak BEFORE the pump impeller. 1. Hi Terri, when you connect the vacuum hose to the skimmer to start vacuuming, this is like increasing the length of the pipe from the pool to the pump, which makes the pump have to work harder, kind of like drinking through a very long straw. Chapter 1: The Evil Emperor's Son. Or switch to Pentair, but I wouldnt say theyre better your case is unusual, the pump may have been dropped, suffered some hard knock from a tree branch, or perhaps it had a defective bearing to begin with. For some time now I have been pushing along with my old cell (t-9 model). Articles and resources for swimming pool owners and DIYers. Do I need to prime it? runs normal on 110 but does not make any sound when set on 230 and wired accordingly. The 1.5 hp pump was so strong you couldnt stand in front of the single return, which is why I used smaller pump. heard a click at the plug. Here is the manual: Now, it could also be rust inside the motor, natural when a pump sits for long periods of time, in a non-climate controlled location. The pool is only 15 months old and I have not had any problems since getting it installed May 2017, other than a small water leak coming from the non suction side of the pump. Good day everyone. Leaks can also come from loose drain plugs, or loose bolts on the seal plate, connecting the motor to the pump. NO one can get the cover off the darn thing. My diffuser does not tightly fit into my seal plate. Hi Chuong, the Leslies RS750CA is the same as the Hayward Super II pump, which are $500-$600. If not, the parts internally, some parts, need replacement. This one is 5 years old. Ive checked all my hoses for clogs and skimmer and pump baskets are clean. After that, putting it to filter (following the backwash) ramps the flow to full strength until the gradual decline cycle starts again. i have a hayward 240 super pump, which have had for about 10 years. Hi Robin, an F5 code? Hi Amy, the timer is usually wired between the pump and the breaker. I have no pressure on my filter. Looks like Ill take it apart tomorrow to see if the impeller is going out or the ceramic bearing may be loose. We are trying to switch the jumper or selector plug (not sure what its called) from 230 to 115 but the jumper doesnt seem to fit smoothly on the 115 setting the prongs it has to slide over seem too far apart and Im afraid of breaking it. Please advise. I would test the voltage at the motor terminal board, very quickly, before the breaker trips, to be sure its between 210V-250V coming in. I just had a power surge in my area and the heater has been turning on and wont turn off. I have a Hayward Super Pump Model:C48L2N134B1 that I replaced 3 or 4 seasons ago and until now I have had no trouble out of it. The spider gasket as it is called, inside of the valve is not sealing the waste port like it should. When in front of the pump, problems like a clogged impeller, air leak into the pump, or clogged skimmer line, or low water these will produce filter pressure lower than normal (on the filter pressure gauge). Hi William, yes an air leak, is what I call it. Shock the pool first and overfilter, before pulling pump. Thanks, "mainEntityOfPage": "https://blog.intheswim.com/hayward-pool-pump-troubleshooting/",
Inground pool, 1 Bought new vac hose now own 3 could be the motor, if the shaft has worn unevenly, or if there are grooves or rust on the shaft. Also check that water level is good in pool, and skimmer weir is not blocking water flow. When the valve is positioned on the filter, it should slide over the standpipe tube, or the center pipe that is connected to the laterals will slide up into the bottom of the valve, and the valve is pushed down to make a tight fit against the filter flange, and then the clamp is supposed to hold it tightly. If not, I would suspect voltage issues, especially with the overheating, be sure pump is wired to accept the incoming voltage (115V or 230V), and it doesnt fluctuate more than 10%, +/- . 5. If you download the owners manual on the Ecostar there is some further information about Drive Errors, and some things you can try, in the troubleshooting section, to verify the fault, and also lists the part number for the drive, if needed. Then dunk them in the pool quickly after the acid, to rinse cleanly. Check the usual spots for air coming into the pump, 1) the threaded pipe coming into the pump (did you use thread sealant? Also check that no wires are touching any metal, and check for any bare/scraped wires. Click OK to extend your time for an additional 0 minutes. I wonder if the lines are clogged or a pipe is partially collapsed. . I changed the sand and it is still occurring. I used electrical tape so the impeller I really dont know how long the motor was running like this when I discover the problem when I discover the problem the motor had already shut off. Hello Dave, If the impeller spins freely, does that mean the shaft is spinning freely or do I need to try to turn it from the back of the motor? If the capacitor is bulged or cracked, or looks like it is burned or charred, you can assume that it is D.O.A. "keywords": "",
Still no luck. It could also be due to the air intake, or the filter pressure, Water around the base, check the motor bolts or seal plate clamp for tightness on the seal plate o-ring, and check drain plugs for tightness, but most likely its coming from around the outlet pipe, and dripping down to the base, or from the shaft seal, which leaks directly mid bottom, where motor connects. Hello there, if he customer wants to install a VS pump (required in 2021 for all new pumps), they could do that now. I just replaced my pump/motor at the start of this swimming season. Is that a reason to replace impeller? In a Quirked world where most people have a superpower-like uniqueness to them, His is among the most dangerous. There should be no elbow after the flow switch. I was only able to read and yes feel voltage in the pool when the main pump was running only. Just opened up the pool and the Hayward Super Pump worked just fine until we started vacuuming the bottom. Hi Javi the capacitor on the motor may have failed. Compare to Hayward T-Cell-15 I had to have a pool person come out & they got me good. Getting air in basket, changed gasket with lube still have the same issue. The main panel feeds a Tork timer, which I dont use the timer, I disconnected the timer motor. Other timers will have a different switch, but all should have someway to override. I need some advice for my 15 x 30 x 48 AG oblong swimming pool. Finally, could be that the voltage is not quite right, one of the legs (power wires) not providing enough power. JavaScript is disabled. "dateModified": "05/20/2022",
Does the mother board need replacing? Check the motor vent holes, (bottom front) to be sure they are not clogged. Hi Sara, could the sound be the gas whistling thru the burner orifices? If there's one thing for certain about pool equipment, is that they will all break down at some point in time. That is usually suitable, but 20 amp could also be used. No moisture. I check electrical from the panel breaker, to the timer to the circuit breakser to the switch to the outlet, through the wire to the pump and power is getting to the pump. You have both filter pump and polaris pump on one timer? The pump has power, turns on, and seals are tight, however it will not cycle the water. Common Salt Chlorine Generator Problems - Pool Research The motor on my Hayward super pump 2 went out so I ordered a Hayward replacement. We just opened our pool up cleaned everything out put new D.E. Well the electrician said it was a bad motor and to contact hayward to replace. second most common is the pump lid or drain plug, lube the lid oring and teflon tape on the drain plug. I have a Hayward H250 pool heater with a digital display. Remove C/B Assy. You might be surprised by how many people neglect to check this area. Thank you so much for taking time to answer all our concerns. Attached please find a copy of the Aqua Plus Operation Manual Please note Section - Configuration Menu Items, Cell Type Selection, page 16. of and in " a to was is ) ( for as on by he with 's that at from his it an were are which this also be has or : had first one their its new after but who not they have We would like to show you a description here but the site wont allow us. partially collapsed, or partially clogged skimmer line. If you have an intermatic clock (big yellow dial), there are a series of gears behind the dial, that all need to be engaged. I have a Hayward super pump 1.5 hp. Hmmm, thats interestng, but I dont think you have a pump problem. Strange things that when I have a storm it doesnt break but I does a day after when day is perfect. Why would the pump and Polaris stop working at the same time? I would suggest replacing the pump with the same exact pump, which is matched to your filter size presumably. All Products, View We recently had a makeover of our backyard where we replaced the concrete with pavers and it could very well be the sands and dust (yes, I had to vacuum the pool a couple times to get it clean) that got into the parts that helped speed up the demise of the pump. Either way, when a DE filter clogs up quickly, it is either not enough DE powder being used, or the grids (flex tubes for Perflex) are clogged with mineral scale or oily deposits. Hi Todd, that would be rare but not impossible sometimes bearings are not set perfectly, or manufactured perfectly, or the tolerances of the bearing housing could be off by a hair, from something being loose, or mis-shaped or if the motor were dropped from a height. If you see any damage, replace your flow switch. Turned on the motor and smoke and a oil type substance came out of the capacitor. Or spray with shaving cream (yes! If the motor shaft wont turn, you can work it loose by spinning the shaft with pliers on the front end of the shaft, or a 7/16 wrench on the back end of the shaft. Could be loose fitting on hoses. No matter what setting I put it in its backwashing the sand into the skimmer. Finally, it could be making the noise at the burner orifice, if one or more is not fully spewing gas, or is not ignited like the rest. Without seeing the union and setup, it is hard to say what is causing it but check for warping of the nut. That motor is sometimes used on the Hayward Superpump which is the only pump with a SQUARE pump basket. Hi John, do you mean the filter top pops off? Third possibility is the pipe size is too small, and your 90 gpm pump may be starved for water. I checked that the switches and other electrical components properly tightened down and everything appears normal. Hi Rob, If the pump is the same exact model and horsepower, it sounds like either; 1). Checked everything still doesnt work . Hi Joe, Low Flow would be indicating that the water flow coming into the pump, heater or salt system is insufficient. Could be too much or too little sand, the filter should be about 2/3 full of sand. The waterfall pump should be a simple system, just a suction line and a return line (no valves? But most likely an air leak, either before or after the pump, pool systems are supposed to be mostly air tight, though most are not completely. I have a new fiberglass pool and ever since I operate it the pump trips the breaker in most cases overnight hours between 2 timing sessions (pump not running). "name": "In The Swim",
To fix the problem, manually reset the Inspect Cell LED. My pump seems to be working fine but Im having an issue with the flow pulsating out of the filter. Tripping the breaker, could possibly be a bad breaker, allowing too much voltage to pass thru to the pump. It would be best to not abandon the pipe if possible, best for water quality, clarity and turnover rates but sometimes thats not feasible so either way will work! Hi Carolyn, When a pump displays those symptoms, its usually an air leak or a collapsed suction hose, or a very dirty filter. Hi Davy, Could be dangerous! 2 year warranty. Could be the use of a clarifier or flocculent that is clogging the sand? It has been in operation since mid May without and incident before yesterday. Wait for the relay to click (5 to 10 seconds). Hi Bill; So you have power coming into your timer or timeclock, but on the out terminals, or the wires that lead to the pump? Yes, if not grounded correctly, the GFCI will trip. new pump started up fine after primed strated to click on and off. Can I turn on this pump without water to check whether the motor is running? However, I havent tried to spin the shaft. It's a little over 3 years old and the cell checked out fine. Appreciate any help. Work through the list below if your Hayward pool heater is on the fritz. Rob, the air leak is coming from the pump, or before the pump. Hi, if the switch wont flip to on, the timer tripper could be right at the point where it is about to trip, making it hard to turn to on. I have a perflex ec50 that is about four years old. Cleaners Controls Filters General Pool/Spa Heat Pumps Heaters Lighting Pumps Robotic Cleaners Sanitization Step 3: Select model to register. How To Fix The Problem Hose it off well, and inspect the tubes for any holes, and if found, replace them with new. So I messed with the wires a little and I got it to turn back on. Terrible storms 2 nights ago. i removed the filter fingers and cleaned numerous times. the 4th wire, the high speed wire. Just got it a couple of weeks ago. Which explains the clicking of the pump. Please help! 3. pipe going into pump 9,000 gallon in ground pool. It is quite rare that while testing a capacitor, it explodes (small explosion), but it can happen. Thanks! Had a ball stuck under the skimmer basket, pump got hot and now will not turn back on.
How To Ask For Clarification Politely, Thompson Cigar Humidor Special, Articles H
Weve not had this issue the past 2 years (we bought the house 2 years ago). Do you think the motor is fried as a result of no water running thru? My pump & filter are Haywards. Hi Rob, there could still have been some sand in the pipes yes, and thats probably the problem. Valves were replaced with pipe and silicone applied to gaskets and O-rings during install and again yesterday while I was checking this list. It seems the pump is more powerful than last year ? Step 3: When the instant salt level is stable (and the negative sign still present), cycle slide switch to 'Super Chlorinate' and back to 'Auto'. Please advise ). If pressure is lower than normal check for air leak on the suction side of the pump, or a clogged impeller, or low water level, stuck skimmer weir, or closed suction valves. Hi Patrick, so you have power from the breaker to the timer and to the switch. rialto grand polished porcelain tile 12x24, platypus gravityworks water filter system kit 2-liter, trinity basics ecostorage 5-tier nsf certified rack, Armstrong Human Resource Management 13th Edition Pdf, what is the newest lens for cataract surgery. Hi Frank, two possible reasons might be nighttime moisture (dew), or small insects, both contacting the circuit, on the timer or connected electrical outlet, and causing a brief short, which can trip the breaker. Put your foot on the motor and apply a little weight, to see if the noise stops. I could take a leap of faith by trying your suggestion of replacing the shaft seal first. Thanks for your insight. Filter runs fine at first, but then eventually loses its umph and then the return becomes minimal. Relays are usually small cubes, about 1 square, sometimes black, sometimes clear, mounted on a circuit board. Make sure that the drive is bonded with the bare copper wire and all four screws are secure on the drive. Hi Gail, overheating can be caused by the wrong wire size from breaker to motor, or loose wire connections, or over-voltage coming into motor, or lack of ventilation around the motor (mulch piled up, or big bushes close by, or placed in a box cover), but its can also be a fatal fault inside the motor. Hi Doug, could be a bad breaker, or bad wiring between the pump and breaker. I dont see any leaks n pressure seems little bit higher than normal. The most common cause for this is turning the valve with the pump on, or not pushing the valve handle down fully as the valve is re-positioned. If no power there, check the timer, if no power there, check the breaker, if no power there Is the main breaker in the house on? If the bolts do not tighten fully, it could be that the housing threaded receivers are loose and spinning as you try to tighten the bolts. 1.5 hayward pool pump motor clicks on and off rapidy. Hi Bryan, not normal but not uncommon. Alternatively, you can spin the shaft at the rear motor, with a 7/16 wrench inserted behind the stationary switch, on the slotted end of the motor shaft. Some pumps are a bit difficult to remove, even when you have removed the right bolts/clamp sometimes they need to be pried apart with a screwdriver, to separate the pump. Hi COnnie, great question! Connect the hose from the pump to PUMP, the wall return pipe to RETURN, and the backwash hose connects to the WASTE port, with the use of a hose adapter and clamp. The new pump runs great and only once every day or so do we notice that the pump is off and that the breaker is tripped. If any of these readings are outside limits, replace motor. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Exterior Wall Covering Materials, Hi Mark, there are salt and ozone resistant shaft seals that can be used, the salt could be the problem, or it could be caused by a water-hammer effect, where flowing water is shut-ff suddenly by a closed valve on the return side, or turning a filter valve while the pump is running. "@type": "ImageObject",
Products, Parts Remove and replace the two seal halves, in the same orientation as removed, spring half slides over impeller stem, donut half is pushed into seal plate. Do you have any suggestions? Seems impeller is not turning, does it turn both ways or one way? To remedy this, simply open up your pump, and clean out any rubbish. This usually means the motor needs to be replaced. Anything I can do on my own to fix this? 24V after the transformer is present. This is our second season for this pump. Have had it for 4-5 years and have had no issues. If a LED is ON, check to see if the flow switch was installed correctly. Perhaps you can replace it with a 20 amp breaker, of the same manufacturer, and youd be all set, or move some of the other devices to draw power from a different breaker. UNK the , . ), you have it primed full of water? If it does, check power inside of the back of the motor, with a test meter. Ive waited a few hours and tried again but no luck. I just want to clarify..we had a problem with the fuse box and its just been changed. Hi David, that would be my first guess, assuming that the power leads are tight, and connections or switches arent loose in the back. Hi Don, if you have four suction lines coming into the pump, that would be skimmer, skimmer, main drain and spa drain? it runs about 30 minutes and trips the breaker. Replace with identical MFD number, printed on capacitor. If you have other questions, you can email me Davy, at swimmers@intheswim.com. Even with the cells reverse polarity feature, the scale will still form on the plates. On a DE filter, water enters the tank through the bottom tank bulkhead, and is when the tank fills up, water is forced through the grids, and then up thru the manifold, and down the standpipe to the top exit bulkhead DE inside the grids, must have been missing an o-ring before, a push-pull valve plunger ring? Hi and thanks for all this knowledge! If youre reading this blog that means you need help troubleshooting your Hayward Aqua Rite salt system. It could also be the wiring from breaker to timer, or timer to pump, or just breaker to pump, if there is no timer or other switch (and if there is no other switch, the breaker is likely just worn out from overuse). The stationary switch copper tabs may be bent, or may have a wire crossing between them, have a loose screw or have some other issue that prevents it from opening, and releasing the capacitor. One thing I discovered is that if I place it in super chlorinate mode today, once the pool pump shuts down for the day, the next day when it turns back on, it will be back in regular chlorinate mode even if the switch is still in super chlorinate mode. The capacitor is like the battery in your car its needed to help get the pump up to speed (3200 RPMs) fast. Diffuser broke. have the pump motor rebuilt by replacing the bearings and shaft seal, or having an electric motor repair shop do it for you, or 2) replace the motor with an exact replacement motor + new shaft seal, or 3). Did I mention low water level, stuck skimmer weirs, or clogged skimmer baskets? . Please remove additional products. My client thinks the motor was 1hp, but he really not sure. I have a maxi-flo 2 and it just stopped working. Why is this happening? If so, the issue would reoccur again, after vacuuming usually. The electrician also installed w new capacitors on the pump and still same problem. Corrosion inside the plug or socket. I have a brand new Hayward super pump, replaced the one that just died. Took it to pool mart and they cleaned it out and said everything was fine inside it. If there is an external 2-speed timeclock, check the wiring, esp. Flip timeclock switch on, inspect time clock motor gears (Intermatic clocks) for good timer motor, and inspect wiring from timer to pump. Additional causes for low water flow in your pump are debris build-up or dirty equipment. The problem lies, where the power dies could be the breaker, time clock, outlet or at the terminal board. Hi Davy, Im trying to remove the impeller from a Hayward 1 HP superpump. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Hi, I have a filter timer and a cleaner timer that are side-by-side. Calling the pool builder for warranty info, too. When I installed the filter and pump the water in the filter came gushing out of the filter and the top mount was raised up even though the clamps were tightly screwed in place. It wont stop leaking. Work through the chart below if your heater displays the following error codes. Thanks in advance for any help you can provide, the pool should be done in the next few days and need to figure out this pump situation. Where can I get a new yellow wire to connect the motor to the switch and see if this solves my issue? Motor may still be good. how to watch past broadcasts on twitch. They can also fail if used on a salt pool (there are salt seals that can be used), or if the motor and shaft heats up to high temps. It looks like I need to change out the pump. Just replaced our pool pump, Hayward 1 hp self priming, super pump. If it is not, re-align your flow switch. The control panel says that theres a driver error. Hi Davy. Look closely at the centrifugal switch on the rear of the shaft, to be sure its tight and is not missing parts (like the springs), engage the switch by hand (power off), to be sure that the stationary switch (located at 6 oclock) is disengaging, or the two copper tabs separate. Now Im getting small air bubbles when the speed is on low. Also could be a loose stationary switch (motor rear, 6 oclock) or a loose centrifugal switch (motor rear, dead center). If from the center of the lid around the stem, you can replace the two small stem o-rings, but sometimes the stem is worn down and needs replacement. Hi Davy! I then plugged the pump into the outlet and it tripped again. How To Recalibrate The Average Salt Level. Your email address will not be published. Use a flashlight, and you should see gears moving thru the small view hole. That is the black cylinder in the rear of the motor, located at 9 oclock. If the switch does not close after the blower starts the control will go into lockout with the blower running. near the end of last season it started loosing its prime on and off. The second thing that can cause such a problem is if the pump is starved for water, cavitating, because it is too large (hp) for the piping system, or because incoming valves are closed, or pipes are plugged, or clogged. Replace with the exact same MFD number printed on the capacitor. Once it finishes calibrating, cycle the Main Switch from AUTO to SUPER CHLORINATE and back to AUTO. La mayora de las veces la vlvula de gas est cerrada, el tanque de propano est bajo, el encendedor est roto o el sensor de fuego no est colocado correctamente. After reinstalling, give it the full charge of DE powder, plus a little extra. The selector plug MUST be moved or the breaker will trip every time you try to start it up. It runs fine but no strong circulation. Lets see what we can do We have our pump timers to shut off at noonmany times, but all the time, they run past the specified shut off time. What should I do? The capacitor is the black cylinder on the left side, you can replace the capacitor at a low cost. If the set screws loosen, the impeller can slide forward and contact the pump housing, and grind both the bronze housing and bronze impeller down rapidly. Inspect the centrifugal switch on the end of the shaft and the stationary switch mounted at 6 oclock and contacting the central centrifugal switch make sure all are intact and tightly secured, and not bent, broken or affected by mud or insects. $8.99 $5.99 As low as $4.49 Dow Corning - Molykote 111 6 gram O-ring Silicone Lubricant and Sealant - Be sure to lube your O-rings to help prevent leaks. Hi, my above ground pool pump will run when not attached to the pool and there is no water in it, but when I get it hooked up to the pool and let the hoses and pump fill, it no longer turns on. The following steps will provide a guide on how to recalibrate a Hayward Aqua Rite. Another piece of information is that the board was replaced back around May of this year as well as the flow sensor. The cord does feel warm to the touch. No reset on the pump motor, but a little water on the wiring, and it will pop a GFI outlet. The centrifugal switch may be loose, or the stationary switch may be bent and not releasing. Any tips on getting the cover off to get to the capacitor (after removing the two screws)? Just opened my in ground pool went to turn the pump on and nothing. Motors have a thermal overload switch which will shut off the motor if it gets too hot to operate, and in such cases, it will turn itself back on again after it cools, usually in 15-20 mins. Could also be a vibration noise, or rocks/pebbles in the pump basket. What you have to do is drain the filter and remove all those tiny bolts, and pull out the entire nest assembly. A local motor shop could probably fix you up for $100, if you can remove the pump, and drive it to their shop. Hi Ernesto, hmmm, Im not quite sure, but sounds like it could be either low voltage, or a loose connection, or something mis-wired between the terminal board and the capacitor? While you have the nest assy out of the tank, after hosing it off, soak it in a DE filter cleaner, to remove any scale and oils. Just bought a new Hayward Perflex Series Extended Cycle Filtration Systems filter and cant get the motor to start. Bump shaft or diaphragm gasket? Not sure whats wrong. This is a salt pool not sure if that matters in the question. You could also use a Hayward 24 sand filter, item E3324. Write Review Hayward AquaTrol HP Main PCB | GLX-PCB-TROL-HP $375.97 Quantity $17.35 / Month * Platinum Preferred Manufacturer Proposition 65 Warning Display seems to be reading correctly and shows the cell is not generating. Put things back together and still have error. Is there something special I need to do when first installing the motor? power to my pool pump & timer quit working at the same time. Hi LInda, humming or buzzing, and not starting could be a few things first check that the shaft is spinning, either by spinning on the impeller end, or at the rear of the motor (power Off in both cases), to be sure the shaft is not bound up or seized. I just went out there to crank them up, after 10 minutes they shut off. Plate appeared to be good. You can remove the cartridge, reassemble the filter and run the system, just to verify that the cartridge is the problem. Hi Rob, I think its a one-year warranty? *If your water temperature reads 215 degrees F, the cell temperature sensor is shorted and your cell needs replacing. Try to spin the impeller with your fingers, or turn the motor shaft to check that it spins freely, or if not, put a wrench on the shaft and break the rust free. Conversely, and by the way, when pressure is much lower than normal, that indicates an obstruction before the filter, like clogged pump or skimmer baskets or an impeller clog. I would say you are likely needing a new motor, and pump. If not the skimmer being blocked, then its an air leak BEFORE the pump impeller. 1. Hi Terri, when you connect the vacuum hose to the skimmer to start vacuuming, this is like increasing the length of the pipe from the pool to the pump, which makes the pump have to work harder, kind of like drinking through a very long straw. Chapter 1: The Evil Emperor's Son. Or switch to Pentair, but I wouldnt say theyre better your case is unusual, the pump may have been dropped, suffered some hard knock from a tree branch, or perhaps it had a defective bearing to begin with. For some time now I have been pushing along with my old cell (t-9 model). Articles and resources for swimming pool owners and DIYers. Do I need to prime it? runs normal on 110 but does not make any sound when set on 230 and wired accordingly. The 1.5 hp pump was so strong you couldnt stand in front of the single return, which is why I used smaller pump. heard a click at the plug. Here is the manual: Now, it could also be rust inside the motor, natural when a pump sits for long periods of time, in a non-climate controlled location. The pool is only 15 months old and I have not had any problems since getting it installed May 2017, other than a small water leak coming from the non suction side of the pump. Good day everyone. Leaks can also come from loose drain plugs, or loose bolts on the seal plate, connecting the motor to the pump. NO one can get the cover off the darn thing. My diffuser does not tightly fit into my seal plate. Hi Chuong, the Leslies RS750CA is the same as the Hayward Super II pump, which are $500-$600. If not, the parts internally, some parts, need replacement. This one is 5 years old. Ive checked all my hoses for clogs and skimmer and pump baskets are clean. After that, putting it to filter (following the backwash) ramps the flow to full strength until the gradual decline cycle starts again. i have a hayward 240 super pump, which have had for about 10 years. Hi Robin, an F5 code? Hi Amy, the timer is usually wired between the pump and the breaker. I have no pressure on my filter. Looks like Ill take it apart tomorrow to see if the impeller is going out or the ceramic bearing may be loose. We are trying to switch the jumper or selector plug (not sure what its called) from 230 to 115 but the jumper doesnt seem to fit smoothly on the 115 setting the prongs it has to slide over seem too far apart and Im afraid of breaking it. Please advise. I would test the voltage at the motor terminal board, very quickly, before the breaker trips, to be sure its between 210V-250V coming in. I just had a power surge in my area and the heater has been turning on and wont turn off. I have a Hayward Super Pump Model:C48L2N134B1 that I replaced 3 or 4 seasons ago and until now I have had no trouble out of it. The spider gasket as it is called, inside of the valve is not sealing the waste port like it should. When in front of the pump, problems like a clogged impeller, air leak into the pump, or clogged skimmer line, or low water these will produce filter pressure lower than normal (on the filter pressure gauge). Hi William, yes an air leak, is what I call it. Shock the pool first and overfilter, before pulling pump. Thanks, "mainEntityOfPage": "https://blog.intheswim.com/hayward-pool-pump-troubleshooting/",
Inground pool, 1 Bought new vac hose now own 3 could be the motor, if the shaft has worn unevenly, or if there are grooves or rust on the shaft. Also check that water level is good in pool, and skimmer weir is not blocking water flow. When the valve is positioned on the filter, it should slide over the standpipe tube, or the center pipe that is connected to the laterals will slide up into the bottom of the valve, and the valve is pushed down to make a tight fit against the filter flange, and then the clamp is supposed to hold it tightly. If not, I would suspect voltage issues, especially with the overheating, be sure pump is wired to accept the incoming voltage (115V or 230V), and it doesnt fluctuate more than 10%, +/- . 5. If you download the owners manual on the Ecostar there is some further information about Drive Errors, and some things you can try, in the troubleshooting section, to verify the fault, and also lists the part number for the drive, if needed. Then dunk them in the pool quickly after the acid, to rinse cleanly. Check the usual spots for air coming into the pump, 1) the threaded pipe coming into the pump (did you use thread sealant? Also check that no wires are touching any metal, and check for any bare/scraped wires. Click OK to extend your time for an additional 0 minutes. I wonder if the lines are clogged or a pipe is partially collapsed. . I changed the sand and it is still occurring. I used electrical tape so the impeller I really dont know how long the motor was running like this when I discover the problem when I discover the problem the motor had already shut off. Hello Dave, If the impeller spins freely, does that mean the shaft is spinning freely or do I need to try to turn it from the back of the motor? If the capacitor is bulged or cracked, or looks like it is burned or charred, you can assume that it is D.O.A. "keywords": "",
Still no luck. It could also be due to the air intake, or the filter pressure, Water around the base, check the motor bolts or seal plate clamp for tightness on the seal plate o-ring, and check drain plugs for tightness, but most likely its coming from around the outlet pipe, and dripping down to the base, or from the shaft seal, which leaks directly mid bottom, where motor connects. Hello there, if he customer wants to install a VS pump (required in 2021 for all new pumps), they could do that now. I just replaced my pump/motor at the start of this swimming season. Is that a reason to replace impeller? In a Quirked world where most people have a superpower-like uniqueness to them, His is among the most dangerous. There should be no elbow after the flow switch. I was only able to read and yes feel voltage in the pool when the main pump was running only. Just opened up the pool and the Hayward Super Pump worked just fine until we started vacuuming the bottom. Hi Javi the capacitor on the motor may have failed. Compare to Hayward T-Cell-15 I had to have a pool person come out & they got me good. Getting air in basket, changed gasket with lube still have the same issue. The main panel feeds a Tork timer, which I dont use the timer, I disconnected the timer motor. Other timers will have a different switch, but all should have someway to override. I need some advice for my 15 x 30 x 48 AG oblong swimming pool. Finally, could be that the voltage is not quite right, one of the legs (power wires) not providing enough power. JavaScript is disabled. "dateModified": "05/20/2022",
Does the mother board need replacing? Check the motor vent holes, (bottom front) to be sure they are not clogged. Hi Sara, could the sound be the gas whistling thru the burner orifices? If there's one thing for certain about pool equipment, is that they will all break down at some point in time. That is usually suitable, but 20 amp could also be used. No moisture. I check electrical from the panel breaker, to the timer to the circuit breakser to the switch to the outlet, through the wire to the pump and power is getting to the pump. You have both filter pump and polaris pump on one timer? The pump has power, turns on, and seals are tight, however it will not cycle the water. Common Salt Chlorine Generator Problems - Pool Research The motor on my Hayward super pump 2 went out so I ordered a Hayward replacement. We just opened our pool up cleaned everything out put new D.E. Well the electrician said it was a bad motor and to contact hayward to replace. second most common is the pump lid or drain plug, lube the lid oring and teflon tape on the drain plug. I have a Hayward H250 pool heater with a digital display. Remove C/B Assy. You might be surprised by how many people neglect to check this area. Thank you so much for taking time to answer all our concerns. Attached please find a copy of the Aqua Plus Operation Manual Please note Section - Configuration Menu Items, Cell Type Selection, page 16. of and in " a to was is ) ( for as on by he with 's that at from his it an were are which this also be has or : had first one their its new after but who not they have We would like to show you a description here but the site wont allow us. partially collapsed, or partially clogged skimmer line. If you have an intermatic clock (big yellow dial), there are a series of gears behind the dial, that all need to be engaged. I have a Hayward super pump 1.5 hp. Hmmm, thats interestng, but I dont think you have a pump problem. Strange things that when I have a storm it doesnt break but I does a day after when day is perfect. Why would the pump and Polaris stop working at the same time? I would suggest replacing the pump with the same exact pump, which is matched to your filter size presumably. All Products, View We recently had a makeover of our backyard where we replaced the concrete with pavers and it could very well be the sands and dust (yes, I had to vacuum the pool a couple times to get it clean) that got into the parts that helped speed up the demise of the pump. Either way, when a DE filter clogs up quickly, it is either not enough DE powder being used, or the grids (flex tubes for Perflex) are clogged with mineral scale or oily deposits. Hi Todd, that would be rare but not impossible sometimes bearings are not set perfectly, or manufactured perfectly, or the tolerances of the bearing housing could be off by a hair, from something being loose, or mis-shaped or if the motor were dropped from a height. If you see any damage, replace your flow switch. Turned on the motor and smoke and a oil type substance came out of the capacitor. Or spray with shaving cream (yes! If the motor shaft wont turn, you can work it loose by spinning the shaft with pliers on the front end of the shaft, or a 7/16 wrench on the back end of the shaft. Could be loose fitting on hoses. No matter what setting I put it in its backwashing the sand into the skimmer. Finally, it could be making the noise at the burner orifice, if one or more is not fully spewing gas, or is not ignited like the rest. Without seeing the union and setup, it is hard to say what is causing it but check for warping of the nut. That motor is sometimes used on the Hayward Superpump which is the only pump with a SQUARE pump basket. Hi John, do you mean the filter top pops off? Third possibility is the pipe size is too small, and your 90 gpm pump may be starved for water. I checked that the switches and other electrical components properly tightened down and everything appears normal. Hi Rob, If the pump is the same exact model and horsepower, it sounds like either; 1). Checked everything still doesnt work . Hi Joe, Low Flow would be indicating that the water flow coming into the pump, heater or salt system is insufficient. Could be too much or too little sand, the filter should be about 2/3 full of sand. The waterfall pump should be a simple system, just a suction line and a return line (no valves? But most likely an air leak, either before or after the pump, pool systems are supposed to be mostly air tight, though most are not completely. I have a new fiberglass pool and ever since I operate it the pump trips the breaker in most cases overnight hours between 2 timing sessions (pump not running). "name": "In The Swim",
To fix the problem, manually reset the Inspect Cell LED. My pump seems to be working fine but Im having an issue with the flow pulsating out of the filter. Tripping the breaker, could possibly be a bad breaker, allowing too much voltage to pass thru to the pump. It would be best to not abandon the pipe if possible, best for water quality, clarity and turnover rates but sometimes thats not feasible so either way will work! Hi Carolyn, When a pump displays those symptoms, its usually an air leak or a collapsed suction hose, or a very dirty filter. Hi Davy, Could be dangerous! 2 year warranty. Could be the use of a clarifier or flocculent that is clogging the sand? It has been in operation since mid May without and incident before yesterday. Wait for the relay to click (5 to 10 seconds). Hi Bill; So you have power coming into your timer or timeclock, but on the out terminals, or the wires that lead to the pump? Yes, if not grounded correctly, the GFCI will trip. new pump started up fine after primed strated to click on and off. Can I turn on this pump without water to check whether the motor is running? However, I havent tried to spin the shaft. It's a little over 3 years old and the cell checked out fine. Appreciate any help. Work through the list below if your Hayward pool heater is on the fritz. Rob, the air leak is coming from the pump, or before the pump. Hi, if the switch wont flip to on, the timer tripper could be right at the point where it is about to trip, making it hard to turn to on. I have a perflex ec50 that is about four years old. Cleaners Controls Filters General Pool/Spa Heat Pumps Heaters Lighting Pumps Robotic Cleaners Sanitization Step 3: Select model to register. How To Fix The Problem Hose it off well, and inspect the tubes for any holes, and if found, replace them with new. So I messed with the wires a little and I got it to turn back on. Terrible storms 2 nights ago. i removed the filter fingers and cleaned numerous times. the 4th wire, the high speed wire. Just got it a couple of weeks ago. Which explains the clicking of the pump. Please help! 3. pipe going into pump 9,000 gallon in ground pool. It is quite rare that while testing a capacitor, it explodes (small explosion), but it can happen. Thanks! Had a ball stuck under the skimmer basket, pump got hot and now will not turn back on.